{"id":1028,"date":"2025-05-19T12:12:14","date_gmt":"2025-05-19T12:12:14","guid":{"rendered":"https:\/\/wisdomlead.ca\/?post_type=product&#038;p=1028"},"modified":"2025-05-19T12:12:14","modified_gmt":"2025-05-19T12:12:14","slug":"ph-controller-hp960rs","status":"publish","type":"product","link":"https:\/\/wisdomlead.ca\/fr\/produit\/ph-controller-hp960rs\/","title":{"rendered":"pH Controller HP960RS"},"content":{"rendered":"<h3>Features<\/h3>\n<ul>\n<li>Simultaneous display of pH(ORP) and Temp.<\/li>\n<li>Microprocessor controllers &#8211; Reliable Monitoring<\/li>\n<li>Simple calibration with sensor<\/li>\n<li>Upper &amp; Lower limit setting &#8211; notification available<\/li>\n<li>Suitable for the field ( Wall, Panel and pipe installation IP65)<\/li>\n<li>Automatic temperature identification (PT1000, NTC30K)<\/li>\n<li>Auto temperature compensation &amp; Notification for calibration<\/li>\n<li>4~20mA , on\/off control function provided<\/li>\n<li>Setting available interval of cleaning<\/li>\n<li>Solution-ground function to minimize sample interference<\/li>\n<li>RS485 communication &amp; MODBUS<\/li>\n<li>Size : 96 x 96 x 145 mm<\/li>\n<\/ul>\n<h3>Specifications<\/h3>\n<table class=\"__se_tbl_ext\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Model<\/span><\/strong><\/p>\n<\/td>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">HP960<\/span><\/strong><\/p>\n<\/td>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">HP960RS<\/span><\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Measuring item<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">pH \/ ORP \/ Temp.<\/span><\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Range<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-family: \uad74\ub9bc; font-size: small;\">pH : -2.00~16.00 pH<br \/>\nORP : -9999 ~ +1999 mV<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Resolution<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-family: \uad74\ub9bc; font-size: small;\">pH : 0.01 pH<br \/>\nORP : 1mV<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Accuracy<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-family: \uad74\ub9bc; font-size: small;\">pH : \u00b10.01 \u00b1 1 digit<br \/>\nORP : \u00b10.1% \u00b1 1 digit<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Temp.<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-size: small;\"><span style=\"font-family: \uad74\ub9bc;\">\u00a0-30.0~130.0 \u2103<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Temp. accuracy<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-size: small;\"><span style=\"font-family: \uad74\ub9bc;\">\u00b10.2 \u00b0C \u00b11digit\u00a0<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Temp. compensation<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-size: small;\"><span style=\"font-family: \uad74\ub9bc;\">\u00a0Automatic temperature identification ,\u00a0\u00a0Pt1000\/NTC30K<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Calibration<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-size: small;\"><span style=\"font-family: \uad74\ub9bc;\">1~3 point\u00a0\u00a0<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Output<\/span><\/strong><\/p>\n<\/td>\n<td>\n<p align=\"center\"><span style=\"font-size: small;\"><span style=\"font-family: \uad74\ub9bc;\"><strong>Analog output x 2<br \/>\n<\/strong>: Isolated DC 0\/4~20mA corresponding to measurement\u00a0\u00a0\u00a0max. load 500\u03a9<\/span><\/span><\/p>\n<\/td>\n<td>\n<p align=\"center\"><span style=\"font-size: small;\"><span style=\"font-family: \uad74\ub9bc;\"><strong>Analog output x 1<br \/>\n<\/strong>: Isolated DC 0\/4~20mA corresponding to measurement\u00a0\u00a0\u00a0max. load 500\u03a9<\/p>\n<p><\/span><\/span><span style=\"font-size: small;\"><span style=\"font-family: \uad74\ub9bc;\"><strong>Digital output x1<br \/>\n<\/strong>: RS485\u00a0\u00a0(MODBUS)<\/span><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Communication<\/span><\/strong><\/p>\n<\/td>\n<td>\n<p align=\"center\"><span style=\"font-family: \uad74\ub9bc; font-size: small;\">x<\/span><\/p>\n<\/td>\n<td>\n<p align=\"center\"><span style=\"font-family: \uad74\ub9bc; font-size: small;\">RS485<br \/>\n(MODBUS)<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Contact output<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Contact output : relay ON\/OFF, max. 240VAC 0.5A<br \/>\nNotification : HI \/ LO Control point<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Washing setting<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-family: \uad74\ub9bc; font-size: small;\">ON : 0~9999 seconds \/ OFF : 0~999.9 hours<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Power output<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-family: \uad74\ub9bc; font-size: small;\">DC\u00b112V<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Water proof<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-family: \uad74\ub9bc; font-size: small;\">IP 65<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Temperature &amp;<br \/>\nHumidity<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-family: \uad74\ub9bc; font-size: small;\">0 ~ 50 \u2103 \/ 5~85%<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Dimension<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-family: \uad74\ub9bc; font-size: small;\">96 X 96 X 145mm \/ 0.4 kg<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p align=\"center\"><strong><span style=\"font-family: \uad74\ub9bc; font-size: small;\">Power supply<\/span><\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p align=\"center\"><span style=\"font-family: \uad74\ub9bc; font-size: small;\">100 ~ 240VAC\u00b110%,\u00a0\u00a0\u00a050\/60Hz<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Features Simultaneous display of pH(ORP) and Temp. Microprocessor controllers &#8211; Reliable Monitoring Simple calibration with sensor Upper &amp; Lower limit setting &#8211; notification available Suitable for the field ( Wall, Panel and pipe installation IP65) Automatic temperature identification (PT1000, NTC30K) Auto temperature compensation &amp; Notification for calibration 4~20mA , on\/off control function provided Setting available [&hellip;]<\/p>\n","protected":false},"featured_media":1029,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[19,31],"product_tag":[],"class_list":{"0":"post-1028","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-istek","7":"product_cat-online-analyzer","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/wisdomlead.ca\/fr\/wp-json\/wp\/v2\/product\/1028","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wisdomlead.ca\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/wisdomlead.ca\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/wisdomlead.ca\/fr\/wp-json\/wp\/v2\/comments?post=1028"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wisdomlead.ca\/fr\/wp-json\/wp\/v2\/media\/1029"}],"wp:attachment":[{"href":"https:\/\/wisdomlead.ca\/fr\/wp-json\/wp\/v2\/media?parent=1028"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/wisdomlead.ca\/fr\/wp-json\/wp\/v2\/product_brand?post=1028"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/wisdomlead.ca\/fr\/wp-json\/wp\/v2\/product_cat?post=1028"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/wisdomlead.ca\/fr\/wp-json\/wp\/v2\/product_tag?post=1028"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}